Checking a pneumatic solenoid valve involves several steps to ensure it's functioning correctly. Here's a basic guide:

1. Visual Inspection:

  • Leaks: Look for any visible air leaks around the valve or fittings. Leaks can indicate worn-out seals or improper connections.
  • Condition: Check for damage, rust, or dirt accumulation. Any of these can affect performance.

2. Check Electrical Connections:

  • Ensure that the electrical connections to the solenoid are intact. Inspect the wiring for any wear or fraying.
  • Test the Solenoid Coil: Use a multimeter to check the coil’s resistance. Compare it with the manufacturer’s specifications to confirm the solenoid coil is functioning properly.
    • If there's no reading or infinite resistance, the solenoid coil may be faulty.

3. Listen for Operation:

  • Energize the valve by applying power to the solenoid and listen for a “click” sound. This indicates the solenoid is activating the valve.
  • If there's no sound, the solenoid may not be working.

4. Check Valve Operation:

  • Manual Override: Many solenoid valves have a manual override function that lets you open or close the valve mechanically. Use this to verify the valve moves when activated.
  • Pressure Test: Apply the specified pressure to the valve and observe the flow. If it's a normally closed valve, there should be no flow when it's de-energized, and it should open when the solenoid is activated. For normally open valves, the flow should be continuous unless powered off.

5. Test for Air Flow:

  • Check Air Flow: With the valve energized, verify the air is flowing through the valve by measuring the output with a flow meter. No flow or reduced flow could indicate a stuck valve or an internal blockage.
  • Check Exhaust: In some valves, the exhaust port can get clogged. Ensure that air can escape freely when the valve is de-energized.

6. Check for Solenoid Response:

  • Power Off/On: Disconnect and reconnect the power supply to see if the solenoid responds to on/off cycles. It should shift positions accordingly.

7. Check for Correct Valving:

  • If the valve is a multi-port (e.g., 3-way or 5-way), check if the appropriate ports are being opened or closed based on the energized or de-energized state.

8. Check for Pulse or Cycle Rate (if applicable):

  • For valves that operate in cycles (like in automated systems), you might need to check the solenoid's pulse rate to ensure it matches the intended cycle speed.

If any of these tests reveal issues like lack of response, leakage, or improper function, the solenoid or valve may need cleaning, repair, or replacement.

CONTACT US
No. 558 Ningkang West Road, Chengnan Street, Yueqing City, Zhejiang Province (within WENZHOU QIAOSEN PNEUMATIC CO. LTD)
Contact Number
+86 15397088192
Carson@Joosungauto.com
ABOUT US


PRODUCTS



WECHAT
WHATSAPP
Copyright WENZHOU QIAOSEN PNEUMATIC CO. LTD. All Rights Reserved.
Pneumatic Solenoid Valve
Pneumatic Gripper
Air Preparation Unit
Pneumatic Cylinder
Cloud computing support Feedback Manage